Why MIRA Is The Preferred Choice For On-Site Rapid Detection?

2026-06-23
조회수 121

MIRA가 현장 신속 진단에 가장 적합한 선택인 이유는 무엇일까요?

Why MIRA is the Preferred Choice for On-Site Rapid Testing?

A Five-Dimensional Comparison of MIRA, PCR, and LAMP

In today's rapidly evolving landscape of molecular diagnostics, nucleic acid amplification has become a key technology. PCR, LAMP, and MIRA (Multienzyme Isothermal Rapid Amplification), independently developed by Amp-future Biotech, each have their own characteristics. Among them, MIRA technology stands out with significant advantages in simplicity and flexible application. We will compare these three technologies across five dimensions: reagents & instruments, assay development, experimental operation, market application, and scientific publication.

news-800-448

 

1. Reagents & Instruments: Minimalist Configuration, Cost-Effective

PCR: Requires a professional thermocycler – expensive and bulky. Traditional qPCR master mixes are prone to inactivation at room temperature, leading to high cold-chain transportation costs.

MIRA: Only requires simple isothermal devices – low equipment cost and highly portable. It uses lyophilized reagents that can be transported and stored at room temperature. Moreover, Amp-future independently supplies the core functional proteins, making the reagents more cost-effective.

2. Assay Development: Simple Design, Shorter Development Cycle

PCR: Primer design must consider Tm values.

LAMP: Requires 4–6 primers – design is tedious and prone to secondary structures, making development difficult. Numerous primer–primer interactions make specificity validation cumbersome.

MIRA: Requires only 2 primers – design principles are simple, with no need for complex parameter optimization. The multi-enzyme synergistic system offers strong resistance to inhibitors, allowing direct amplification of crude samples. This significantly shortens the development cycle and enables rapid response to the need for detection products during public health emergencies.

3. Experimental Operation: One-Step, Efficient, and Convenient

PCR: The workflow is complex, requiring repeated pipetting and thermal cycling, which demands highly trained personnel. It typically takes about 1.5 hours.

LAMP: Although it operates under isothermal conditions, the primer and enzyme systems are complex, making pipetting error-prone. Opening the tube after amplification can easily cause aerosol contamination. The reaction takes 40–60 minutes.

MIRA: Uses a mild reaction temperature (39–42°C) with an extremely low risk of aerosol contamination. It enables one-step operation with no need to open the tube after sample addition. The entire process takes only 5–20 minutes, and non-professionals can quickly master it.

news-1000-468

4. Market Application: Diverse Scenarios, Strong Field Deployability

PCR: Primarily used for precise laboratory testing and is not well suited for on-site rapid detection. High equipment costs and lack of portability limit its use in grassroots and field settings.

LAMP: Can be used for some on-site detection, but on-site rapid testing demands "results in minutes" – a speed advantage LAMP does not offer. Opening the tube in the field also poses a high risk of environmental contamination.

MIRA: With its advantages of speed, portability, and simplicity, users can carry compact instruments and lyophilized reagents directly to the front line. It is widely used in human medical diagnostics, animal disease detection, aquaculture, food safety, agricultural and forestry testing, and many other fields – demonstrating far greater field applicability than competing technologies.

news-700-319

5. Scientific Publication: High-Quality Data, Strong Recognition

PCR: Although widely used, the technology is mature with limited room for innovation, making it difficult to publish in high-impact journals. Experimental reproducibility is often affected by equipment and operator variability, resulting in moderate data stability.

LAMP: Research interest remains high, but primer design and specificity issues can undermine the persuasiveness of the data, affecting journal acceptance rates.

MIRA: MIRA technology is highly versatile and can be combined with CRISPR, microfluidics, sequencing, and other techniques, offering strong research innovation. It achieves a detection sensitivity of 1–5 copies/μL with excellent specificity and reliable data, making it a hot topic in the field of molecular detection.

Amp-future Biotech's MIRA technology, with its core strengths of accuracy, reliability, speed, and simplicity, breaks the stereotype that nucleic acid amplification can only be performed in a laboratory. Whether used in laboratory research or frontline applications, MIRA consistently demonstrates flexibility and reliability.

MIRA 기술은 기존 핵산 증폭 기술의 한계를 극복하여 **"실험실 밖에서도 가능한 분자 진단"**을 구현한 것이 핵심입니다.

구분PCR (중합효소 연쇄 반응)LAMP (고리 매개 등온 증폭)MIRA (다중효소 등온 신속 증폭)
장비고가, 대형, 정밀 온도 제어등온 장치저가, 초소형, 휴대용 등온 장치
시간약 90분40~60분5~20분 (초고속)
시약 보관냉장/냉동 필수 (콜드체인)복잡한 효소 시스템상온 보관/운송 가능 (동결 건조)
편의성전문가 필요, 복잡한 단계파이펫팅 오류 및 오염 위험원스텝, 비전문가도 사용 가능
민감도높음보통 (특이성 이슈 발생 가능)매우 높음 (1-5 copies/uL)

news-930-1083news-900-959

 NameCataloguePack infoPrice(-VAT)Shelf lifeProduct description
Fluorescence DetectorIsothermal Fluorescence DetectorWL-16-IV1unit/box₩10,000,0005 year1. Suitable for fluorescence signal detection
2. FAM/VIC dual-channel, displaying real-time fluorescence curves;
3. 16-well throughput, with independent operation of AB chambers.
Digital Isothermal Detector WL-PS-8C1unit/box₩2,500,0003 year1. Suitable for fluorescence signal detection
2. Single FAM channel, displays results using the endpoint method;
3. 8 throughputs,  portable device
LFS DevicePocket INAAT HeaterWL-HC-1A1unit/box₩70,0003 year1. Applicable to products based on MIRA test strip assay.
2. Combined with consumable unit, read results via test line.
Nucleic Acid Purification SystemNucleic Acid Purification System Mini P4WL-NA-P41unit/box₩6,000,0005 yearThe Mini P4 is a compact, fully automated nucleic acid purification system designed for rapid and efficient extraction using magnetic bead technology. With its 4-channel throughput and small footprint, it is ideal for laboratories requiring flexible, low- to medium-throughput sample processing.
Nucleic Acid Purification System Mini P16WL-NA-P161unit/box₩7,000,0005 yearThe Mini P16 is a fully automated nucleic acid purification system that combines high efficiency with a compact design. Featuring 16-channel throughput, it enables higher sample processing capacity while maintaining reliable and consistent performance through magnetic bead–based extraction.
All-in-one deviceAutomated Isothermal Nucleic Acid Amplification Detection SystemWL-GM-X41unit/box₩55,300,0005 yearThe WL-GM-X4 Fully Automated Isothermal Nucleic Acid Amplification Analyzer is an integrated system that combines nucleic acid extraction and amplification-based detection. When used together with compatible reagent kits, it enables target nucleic acid extraction, isothermal amplification, and fluorescence-based detection and analysis. The instrument supports a sample throughput of four samples per run and is equipped with a dual-channel fluorescence detection system.
  Rapid Detection Package For Field Use   
Digital Isothermal Fluorescence Detector
Version
NameSpec.QTYPrice(-VAT)Upgrade to a standard hard case: + USD 30. 
Digital Isothermal Fluorescence Detector 8 wells1  
UPS Portable Power Supply24V/3A1  
Pipette/1  
Boxed sterile filter pipette tips (RNase-free)96T1₩3,500,000 
Self-sealing sampling bags100/pack1  
Grinding rods100/pack1  
Centrifuge tube rack (0.2 mL)96 wells2  
Centrifuge tube rack (2 mL)24 wells1  
Rapid Test Kit Bag (soft case)37*26*131  
Pocket INAAT Heater
Version
  Upgrade to a standard hard case: + USD 30. 
NameSpec.QTY  
Pocket INAAT Heater1 well2  
Portable Power Supply5V/2A1  
Pipette/1₩1,200,000 
Boxed sterile filter pipette tips (RNase-free)96T1  
Self-sealing sampling bags100/pack1  
Grinding rods100/pack1  
Centrifuge tube rack (2 mL)24 wells1  
Rapid Test Kit Bag (soft case)35*23*121 Updated date : 2026-05-27
Pocket INAAT Consumable UnitPocket INAAT Consumable UnitWL-HC-1A-ZJ24T/包₩254,000Including nucleic acid test strips, diluent, and reaction chamber ( no reagents)
Pocket INAAT  DNA  Amplification UnitWLN8203HC2424T/包₩441,000DNA/RNA research reagent cartridge components, including a single-target nucleic acid lateral flow strip, dilution buffer, and a reaction chamber (containing DNA or RNA test strip reagents and a stirring bar).
Pocket INAAT  RNA  Amplification UnitWLRN8209HC2424T/包₩450,000